Text Size: A+| A-| A   |   Text Only Site   |   Accessibility
Qualifying Water Heaters
General Information
 NOTES:
  • "EF" means energy factor (dimensionless).
  • "E" means electrically operated system.
  • "NG/P" means natural-gas- or propane-fired system.
  • Water heaters (WH) are categorized into four tax credit tiers depending on their performance:
Tier WHE1 - savings of 1000 kilowatt-hours - $400 tax credit amount
Tier WHE2 - savings of 1,395 kilowatt hours - $560 tax credit amount
Tier WHG1/P - savings of 45 therms - $215 tax credit amount
Tier WHG2/P - savings of 71 therms - $340 tax credit amount
  • Tax credit amounts may be limited by the "25 percent of net cost" maximum (see information pages).
  • Savings are in kilowatt-hours for electric units, therms for natural gas- or propane-fired units.
  • Level WHE2 assumes a ducted installation, set up to use the home´s exhaust air stream, or other pre-heated air, as the energy source. Level WHE1 assumes the unit uses ambient air as a heat source.
    All electric models are heat pumps.
  • For instantaneous units used in a storage mode, with one or more storage tanks, storage must be insulated to a nominal R-16. Tanks without equivalent bottom or top insulation must be installed with bottom boards, whether indoors or out.
  • Installation costs in excess of those associated with a conventional water heater can be used when computing the maximum tax credit amount (maximum of tax credit shown versus 25 percent of the net cost).
  • Conventional tank-type water heaters are not efficient enough to qualify for a tax credit.
     
     For more information, contact us at (503) 378-4040 in the Salem area or (800) 221-8035 toll free in Oregon. We can also be reached via email at energyweb.incoming@state.or.us.

Qualifying Water Heaters as of January 2008
AQUA PRODUCTS/YORK HEAT PUMP
 
Electric Heat Pump
 

Model # COP Maximum
Firing Rate
(Btu/hr)
Minimum
Firing Rate
(Btu/hr)
Type Maximum
Tax Credit
ASCHP-024S2A 2.80 NA NA WHE1 $400
ASCHP-036S2A 2.80 NA NA WHE1 $400
ASCHP-048S2A 2.80 NA NA WHE1 $400

BOSCH/AQUASTAR
 
Gas Tankless
 
Model # EF Maximum
Firing Rate
(Btu/hr)
Minimum
Firing Rate
(Btu/hr)
Type Maximum
Tax Credit
GWH 715 ES (Pro) 0.81 199,000 19,900 WHG2 $340
GWH 800 ES (Pro) 0.89 199,000 19,900 WHG2 $340
 

BRADFORD-WHITE
 
Gas Tankless
 
Model # EF Maximum
Firing Rate
(Btu/hr)
Minimum
Firing Rate
(Btu/hr)
Type Maximum
Tax Credit
IGI-180R-10N 0.82 180,000 15,000 WHG2 $340
IGE-199R-10N 0.82 199,000 15,000 WHG2 $340

E-TECH
 
Electric Heat Pump
 
Model # COP Maximum
Firing Rate
(Btu/hr)
Minimum
Firing Rate
(Btu/hr)
Type Maximum
Tax Credit
R-60 3.30 NA NA WHE1 $400
R-106K-5 3.40 NA NA WHE1 $400
R-106H 3.20 NA NA WHE1 $400
R-106H w. duct kit 3.20 NA NA WHE2 $560

LENNOX
 
Gas Tank-Type
 
Model # EF Maximum
Firing Rate
(Btu/hr)
Minimum
Firing Rate
(Btu/hr)
Type Maximum
Tax Credit
HM30-100 0.86 100,000 NA WHG2 $340
HM30-150 0.86 150,000 NA WHG2 $340
HM61-100 0.83 100,000 NA WHG2 $340
HM61-130 0.81 130,000 NA WHG2 $340
HM61-150 0.81 150,000 NA WHG2 $340

MONITOR PRODUCTS
 
Gas Tankless
 
Model # EF Maximum
Firing Rate
(Btu/hr)
Minimum
Firing Rate
(Btu/hr)
Type Maximum
Tax Credit
MWH180 0.81 180,000 22,500 WHG2 $340

NORITZ AMERICA CORP
 
Gas Tankless
Model # EF Maximum
Firing Rate
(Btu/hr)
Minimum
Firing Rate
(Btu/hr)
Type Maximum
Tax Credit
N-063S* 0.81 175,000 24,000 WHG2 $340
N-069M* 0.81 194,000 21,000 WHG2 $340
N-0751M 0.84 199,000 12,000 WHG2 $340
N-075M* 0.84 199,000 12,000 WHG2 $340
N-084M*1 
(see note)
0.80 236,000 21,000 WHG2 $340
 
1 Note on Noritz model N-084M - currently this model is classified by the Oregon Mechanical
Code as a boiler and has special inspection requirements.  Consult your local Building Department for current regulations.      


PALOMA
 
Gas Tankless
 
Model # EF Maximum
Firing Rate
(Btu/hr)
Minimum
Firing Rate
(Btu/hr)
Type Maximum
Tax Credit
PH-20R* 0.82 141,000 21,000 WHG2 $340
PH-28R* 0.82 199,000 19,000 WHG2 $340
PTG-74** 0.82 199,000 19,000 WHG2 $340

POLARIS
 
Gas Tank-Type
 
Model # EF Maximum
Firing Rate
(Btu/hr)
Minimum
Firing Rate
(Btu/hr)
Type Maximum
Tax Credit
PG**34-100-2*V 0.83 100,000 NA WHG2 $340
PG**34-130-2*V 0.81 130,000 NA WHG2 $340
PG**34-150-2*V 0.81 150,000 NA WHG2 $340
PG**50-130-2*V 0.83 130,000 NA WHG2 $340
PBG102-34S100-2 0.82 100,000 NA WHG2 $340
PBG102-50T100-2 0.84 100,000 NA WHG2 $340

RHEEM (Gas Tank-Type)
 
 
 
Model # EF Maximum
Firing Rate
(Btu/hr)
Minimum
Firing Rate
(Btu/hr)
Type Maximum
Tax Credit
HE45-199 0.85 199,000 NA WHG2 $340
HE45-160 0.83 160,000 NA WHG2 $340
HE45-130 0.86 130,000 NA WHG2 $340
HE45-100 0.85 100,000 NA WHG2 $340
HE80-160 0.83 160,000 NA WHG2 $340
HE80-130 0.85 130,000 NA WHG2 $340
 

RHEEM (Gas Tankless)
Model # EF Maximum
Firing Rate
(Btu/hr)
Minimum
Firing Rate
(Btu/hr)
Type Maximum
Tax Credit
RTG-53 0.82 145,000 21,600 WHG2 $340
RTG-74 0.82 199,900 19,000 WHG2 $340
GT-199 0.82 199,000 19,000 WHG2 $340

RINNAI "Continuum"
 
Gas Tankless
 
Model # EF Maximum
Firing Rate
(Btu/hr)
Minimum
Firing Rate
(Btu/hr)
Type Maximum
Tax Credit
LSi 0.82 180,000 15,000 WHG2 $340
LS* 0.82 199,000 15,000 WHG2 $340
C53i  0.81 180, 000 15,000 WHG2 $340
C85e  0.82 199,000 15,000 WHG2 $340
C85i  0.80 180, 000 15,000 WHG2 $340
R53i  0.82 180, 000 15,000 WHG2 $340
R70e  0.81 199,000 15,000 WHG2 $340
R85e  0.82 199,000 15,000 WHG2 $340
R85i  0.80 180, 000 15,000 WHG2 $340

RUUD
 
Gas Tankless
 

Model # EF Maximum
Firing Rate
(Btu/hr)
Minimum
Firing Rate
(Btu/hr)
Type Maximum
Tax Credit
RUTG-53 0.82 145,000 21,600 WHG2 $340
RUTG-74 0.82 199,900 19,000 WHG2 $340
GT-199 0.82 199,000 19,000 WHG2 $340

TAKAGI
 
Gas Tankless
 
Model # EF Maximum
Firing Rate
(Btu/hr)
Minimum
Firing Rate
(Btu/hr)
Type Maximum
Tax Credit
FLASH/T-H1 0.92 199,000 15,000 WHG2 $340
FLASH/T-K1S 0.83 190,000 15,000 WHG2 $340
T-KD20  0.84 185,000 20,000 WHG2 $340
FLASH/T-K2 0.84 185,000 20,000 WHG2 $340
FLASH/T-K3 0.83  199,000 11,000 WHG2 $340
FLASH/T-KJr. 0.83 140,000 19,500 WHG2 $340
1 Note on Takagi model T-M1- currently this model is classified by the Oregon Mechanical
Code as a boiler and has special inspection requirements.  Consult your local Building Department for current regulations.
 

TREVOR-MARTIN
 
Electric Heat Pump
 
Model # COP Maximum
Firing Rate
(Btu/hr)
Minimum
Firing Rate
(Btu/hr)
Type Maximum
Tax Credit
WCC12 2.10 NA NA WHE1 $400
WCC12 2.60 NA NA WHE2 $560

UTICA BOILER "WatterSaver"
 
Electric Heat Pump
 
Model # COP Maximum
Firing Rate
(Btu/hr)
Minimum
Firing Rate
(Btu/hr)
Type Maximum
Tax Credit
HPWH-50 2.00 NA NA WHE1 $400

VOYAGER
 
Gas Tank-Type
 
Model # EF Maximum
Firing Rate
(Btu/hr)
Minimum
Firing Rate
(Btu/hr)
Type Maximum
Tax Credit
SSV90-45S 0.85 90,000 NA WHG2 $340
SSV90-50S 0.85 90,000 NA WHG2 $340
SSV100-45R 0.85 100,000 NA WHG2 $340
SSV100-50R 0.85 100,000 NA WHG2 $340
SSV130-30D 0.86 130,000 NA WHG2 $340
SSV130-45R 0.86 130,000 NA WHG2 $340
SSV130-50R 0.86 130,000 NA WHG2 $340
SSV130-45S 0.86 130,000 NA WHG2 $340
SSV130-50S 0.86 130,000 NA WHG2 $340
SSV130-80R 0.85 130,000 NA WHG2 $340
SSV130-80S 0.85 130,000 NA WHG2 $340
SSV130-119R 0.84 130,000 NA WHG2 $340
SSV130-119S 0.84 130,000 NA WHG2 $340
SSV160-45S 0.83 160,000 NA WHG2 $340
SSV160-50S 0.83 160,000 NA WHG2 $340
SSV160-80R 0.83 160,000 NA WHG2 $340
SSV160-119R 0.84 160,000 NA WHG2 $340
SSV199-45S 0.85 199,000 NA WHG2 $340
SSV199-50S 0.85 199,000 NA WHG2 $340
SSV199-80R 0.85 199,000 NA WHG2 $340
SSV199-119R 0.84 199,000 NA WHG2 $340
SSV199-119RB 0.84 199,000 NA WHG2 $340

WAIWELA
 
See Paloma
 

 
Page updated: March 20, 2008

Get Adobe Acrobat ReaderAdobe Reader is required to view PDF files. Click the "Get Adobe Reader" image to get a free download of the reader from Adobe.